Search results for "dynamic contrast-enhanced MRI"
showing 10 items of 17 documents
Enhancement pattern of hepatocellular adenoma (HCA) on MR imaging performed with Gd-EOB-DTPA versus other Gd-based contrast agents (GBCAs): An intrai…
2019
Purpose: To conduct an intraindividual comparison of the enhancement pattern of hepatocellular adenoma (HCA) on dynamic MRI study obtained following the injection of Gadoxetic acid (Gd-EOB-DTPA) and other gadolinium-based contrast agents (GBCAs).Method: This is a retrospective, Institutional Review Board-approved study conducted in a single institution. A search of medical records between 2008 and 2017 revealed 17 patients (all females) with at least one pathologically-proven HCA who underwent liver MRI with Gd-EOB-DTPA and another GBCA within 1 year. Enhancement of each lesion on hepatic arterial (HAP), portal venous (PVP), 2 min and 4-5 minutes phases was subjectively evaluated by two abd…
Assessment of tumor microcirculation with dynamic contrast-enhanced MRI in patients with esophageal cancer: initial experience.
2008
PURPOSE: To investigate the feasibility and impact of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on tumor characterization and response to radiochemotherapy (RCT) in patients with esophageal cancer. MATERIALS AND METHODS: A total of 48 patients underwent DCE-MRI to assess tumor microcirculation based on a two-compartment model function. Effects of RCT on kinetic parameters were studied in 12 patients with squamous cell carcinoma. RESULTS: Tumor microcirculation differs with respect to histological subtype: squamous cell carcinomas showed lower values of amplitude A (leakage space, P = 0.015) and higher contrast agent exchange rates (k(21), P = 0.225) compared with adenoc…
Magnetically labeled water perfusion imaging of the uterine arteries and of normal and malignant cervical tissue: initial experiences.
1998
Purpose: The aim of this pilot study was to evaluate a magnetically labeled water perfusion imaging technique as a non-contrast-enhanced approach to demonstrate the uterine artery, its branches, and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma (FIGO IIB-IVA). Methods and Materials: Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by magnetically labeled water perfusion imaging at different inversion delay times (300–900 ms). The magnetic resonance imaging (MRI) findings of all patients were…
Contrast-enhanced second-harmonic sonography in the detection of pseudocapsule in renal cell carcinoma.
2004
“OBJECTIVE. Our purpose was to assess the capacity of contrast-enhanced second-harmonic sonography to detect a pseudocapsule in renal masses compared with conventional gray-scale sonography. SUBJECTS AND METHODS. Thirty-two patients with 40 renal masses suspicious for renal cancer (mean diameter, 3.1 cm) were prospectively studied with contrast-enhanced second-harmonic sonography during IV administration of a second-generation sonographic contrast agent. The sonographic criteria for the presence of a pseudocapsule were a peritumoral hypoanechoic halo on conventional gray-scale imaging and a rim of perilesional enhancement, increasing in the tardive phase of the examination, on contrast-enha…
Cervical carcinoma: standard and pharmacokinetic analysis of time-intensity curves for assessment of tumor angiogenesis and patient survival
1999
Since detailed knowledge regarding the pathophysiological properties—which in turn are responsible for differences in contrast enhancement—remain fairly undetermined, it was the aim of this study (i) to examine the association of standard and pharmacokinetic analysis of time-intensity curves in dynamic MRI with histomorphological markers of tumor angiogenesis (microvessel density [MVD]; vascular endothelial growth factor [VEGF]) and (ii) to determine the ultimate value of a histomorphological and a dynamic MRI approach by correlation of those data with disease outcome in patients with primary cancer of the uterine cervix. Pharmacokinetic parameters (amplitude A, exchange rate constantk 21) …
Eine Kombination niedrig und hochauflösender dynamischer T1-gewichteter Sequenzen zur besseren Beurteilung der Morphologie Kontrastmittel aufnehmende…
2002
Purpose: Presentation of a new protocol for simultaneous acquisition of both low and high resolution T 1 -weighted images of breast lesions for dynamic contrast-enhanced MR mammography. Demonstration of possible diagnostic improvement with representative measurements in patients with suspected breast cancer by adding morphologic parameters from high resolution sequences to the analysis of the signal-time curve. Materials and Methods: Dynamic MR imaging was performed with a 1.5 T system (Magnetom SONATA, Siemens Medical Systems, Germany) and the manufacturer's double-breast coil. Coronal T 1 -weighted 3D FLASH sequences (spatial resolution 1.25 ×1.25 mm 2 ; slice thickness 1.7 mm) were acqui…
Hyperpolarized 3helium gas as a novel contrast agent for functional MRI of ventilation.
2002
The use of inhaled hyperpolarized 3He gas in MRI is a recent approach for ventilation imaging. It has recently received enormous interest since it is capable of producing new and regional information on normal and abnormal lung ventilation. Promising preclinical and preliminary clinical results are the driving force to start phase II trials with patients suffering from obstructive and restrictive lung diseases.
Dynamic19F-MRI of pulmonary ventilation using sulfur hexafluoride (SF6) gas
2001
A new method for dynamic imaging of pulmonary wash-in and wash-out kinetics of inhaled sulfur hexafluoride (SF6) gas was developed. Measurements at the fluorine-19 Larmor frequency were performed in pigs using a gradient echo pulse sequence with 0.5 ms echo time and a measurement time of 9.1 s per image. Dynamic MRI was performed during wash-in and wash-out of SF6 gas in mechanically ventilated porcine lungs. A postprocessing strategy was developed for quantitative determination of wash-out time constants in the presence of noise. Mean wash-out constants were 4.78 ± 0.48 breaths vs. 4.33 ± 0.76 breaths for left and right lung when ventilation was performed with low tidal volume, and 1.73 ± …
Dynamic contrast-enhanced MRI parameters as biomarkers for the effect of vatalanib in patients with non-small-cell lung cancer.
2014
ABSTRACT: Aims: To assess the utility of dynamic contrast-enhanced MRI parameters in the demonstration of early antiangiogenic effects and as prognostic biomarkers in second-line treatment of advanced-stage non-small-cell lung cancer with vatalanib. Patients & methods: The transfer constant (Ktrans) and the initial area under the contrast concentration–time curve at 60 s (AUC60) were assessed in 46 patients. Changes were compared with response evaluation from computed tomography imaging and Response Evaluation Criteria In Solid Tumors guidelines. Results: Statistically significant mean reductions in Ktrans (38.4%; p < 0.0001) and AUC60 (24.9%; p < 0.0001) were found at day 2. Af…
Dynamic Fast Imaging Employing Steady State Acquisition Magnetic Resonance Imaging of the Vocal Tract in One Overtone Male Singer: Our Preliminary Ex…
2022
Summary Aims To demonstrate physiological changing of vocal tract's structures during overtone singing with commercial magnetic resonance imaging (MRI) Fast Imaging Employing Steady State Acquisition (FIESTA) dynamic sequence. Methods and Materials A 1.5 T MRI with a 16 channel head-and-neck coil and a FIESTA sequence were used. A temporal resolution of 0.155 sec (7 image/s). A single professional singer was studied. The MR acquisition is made while the singer performed a predetermined singing sequence. Three different overtone singing techniques were examined (L-technique, J-technique, and NG technique) and one effect (Ezengileer) applied to L-technique. For each overtone technique we eval…